>Product>Electrical Test Equipment>Electrical Calibrator>Smart Three Phase Transducer Calibrator
GF302B portable smart three phase transducer calibrator is suitable for power plant and power grid companies for the following function: measuring and testing department and instrumentation classes, national levels measuring and testing institutions, railway, petroleum, chemical industry and other large industrial and mining enterprises, scientific research units, etc. The core technology function with 32bit digital signal processor (DSP+MCU) and 24 high-speed digital A/D converters composed of high precision work frequency communication terminal. It can test the basic error of power transducer, the change caused by the influence of voltage, current, waveform, power factor, etc., and the ripple content and response time in the output DC voltage (current) of the transducer. Also as standard three phase ac voltage source and current source, or as DC power source. It is one ideal high precision calibrator in electrical laboratory.
■ Power plant; ■ Universities; ■ Research institutes; ■ Transducer manufacturers; ■ Electrical testing center; ■ Power meter manufacturers; ■ Panel meter manufacturers; ■ Pointer meter manufacturers; ■ Digital meter manufacturers; ■ Railway electrical department; ■ ISO17025 Electrical laboratory; ■ Power engineering commissioning company; ■ Electricity power bureau & power company; ■ Electrical Department of industrial and mining enterprises;
■ Adopt 32-bit MCU+DSP processor, powerful and flexible;
■ 8.4 inch big screen color display and English interface;
■ With USB & RS232 port, it can connect computer for data management or controlled by PC;
■ For the software calibration, you don't need to open the case, it's stable and reliable;
■ Wide temperature core devices are used to ensure the long-term accuracy of the equipment;
■ With automatic failure detection function, shows fault part, the convenience users check line;
■ Voltage output terminal with short circuit, current output terminal open protection and power amplifier overheating protection function;
■ As one voltage source, current source and power source with high precision and high stability standard resource;
■ The built-in electric measurement transducer, electric measurement instrument and meter instructions of verification program, fully automatic or semi-automatic for verification, and save 10000 group test data;
■ Check all kinds of electric measurement indicating meter, including AC/DC voltmeter, AC/DC ammeter, frequency meter, phase angle meter, single & three-phase ac active power meter, three-phase ac reactive power meter & synchronous meter etc;
■ All kinds of electric measurement transducer can be tested, including AC/DC voltage transducer, AC/DC current transducer, frequency transducer, power factor transducer, single/ three-phase AC active power transducer, three-phase reactive power transducers;
Electrical parameters | |
---|---|
Accuracy class | 0.05% |
Power supply | Single phase AC 220V±10% or 110V±10%, 50/60Hz |
AC Voltage output | |
Range(U1,U2,U3) | 140V, 280V, 600V |
Adjusting range | (0-120)% RG |
Adjust fineness | 0.01% RG, 0.1% RG, 1% RG, 10% RG |
Accuracy | 0.05% RG |
Stability | 0.01% / 1 min |
Distortion | ≤0.2% (non-capacitive load) |
Load capacity | 25VA |
Output distortion degree | ≤0.2% or (linear load) |
AC Current output | |
Range(I1,I2,I3) | 0.2A, 1A, 10A, 20A |
Adjusting range | (0-120)% RG |
Adjust fineness | 0.01% RG, 0.1% RG, 1% RG, 10% RG |
Accuracy | 0.05% RG |
Stability | 0.01%/1 min |
Distortion | ≤0.2% (non-capacitive load) |
Load capacity | 25VA |
Output distortion degree | ≤0.2% or (linear load) |
AC Power output | |
Accuracy | 0.05% RG |
Stability | 0.01%/1min |
Frequency | |
Frequency range | 40.000 - 70.000 Hz |
Resolution | 0.001 Hz |
Accuracy | 0.005 Hz |
Power factor output | |
Adjusting range | -1 ~ 0 ~ 1 |
Adjust fineness | >0.0001 |
Accuracy | >0.0005 |
Phase angle | |
Scope | 0°-359.99° |
Resolution | 0.01° |
Accuracy | 0.05° |
Voltage/Current harmonic output | |
Times | 2-31st |
Content | 0-40% |
Phase | 0-359.999 degree |
Configuration error | (10% RD + 0.1%), RD refers to the configuration value of harmonic contents |
DC Voltage output | |
Range | 5V, 65V, 500V, 1000V |
Adjusting range | (0-120)% RG |
Adjust fineness | 0.01% RG, 0.1% RG, 1% RG, 10% RG |
Accuracy | 0.05% RG |
Stability | 0.01%/1min |
Load capacity | 25VA |
Ripple content | ≤1% |
DC Current output | |
Range | 0.1A, 0.2A, 1A, 10A, 20A |
Adjusting range | (0-120)% RG |
Adjust fineness | 0.01% RG, 0.1% RG, 1% RG, 10% RG |
Accuracy | 0.05% RG |
Stability | 0.01%/1min |
Load capacity | 25VA |
Ripple content | ≤1% |
DC measurements | |
DC voltage measurement range | 0 to ±10V |
DC current measurement range | 0 to ±24mA |
Measurement accuracy | 0.01% RG |
Functions | |
LCD display | 8.4inch touch TFT color LCD |
Data recorder | 16G, 10000sets |
Programmable | by RS232 |
Communication port | USB, RS232, 10/100M LAN |
Auto test software | Yes |
Standard | |
Standard | JJG126-1995, JJG_597-2017, Q/GDW 1899-2013, DL/T1119-2009, DL/T630-1997, JJG124-2005; JJF1587-2016; IEC61010, IEC 61000, IEC 61326 |
Safety | |
Isolation protection | IEC 61010-1:2001 |
Measurement Category | 300 V CAT III, 600 V CAT II |
Degree of protection | IP20 |
Declaration of conformity | CE, CNAS certified |
Mechanical parameters | |
Dimensions (W×D×H) (mm) | 460x430x185 |
Weight (kg) | 25 |
Environmental conditions | |
Working temperature | 0°C to 40°C |
Storage conditions | -30°C to 60°C |
Relative humidity | ≤85% |
(1) RG means range, the same as below; (2) RD means the setted harmonic content, harmonic can be a single output, also multiple output. |