The T-315 battery tester is controlled by microprocessor, and the internal 16 bit ADC can accurately detect the battery internal resistance, voltage and temperature. It is characterized by measuring without stopping the UPS system, using AC low resistance measurement and noise reduction technology, without stopping the normal operation of the tested equipment, and measuring under the running state, which greatly shortens the test time. At the same time, it has the functions of histogram display, data upload to computer, PDA and other intelligent devices, such as Bluetooth connection for wireless measurement, data access and so on.
DESCRIPTIONThe T-315 battery tester is a measuring instrument used to measure the internal resistance, voltage and temperature of rechargeable batteries such as lead-acid battery and lithium battery, so as to judge the battery health status. At the same time, it can be used as an instrument to measure the ESR parameters of electrolytic capacitor (for reference only). The instrument uses the AC 4-terminal test method to measure the internal resistance of the battery, and can measure the correct measurement value without being affected by the contact resistance between the test line, terminal and battery electrode. At the same time, it also has the functions of data storage, data access, alarm, automatic shutdown and so on. The whole machine has the advantages of high-grade and beautiful appearance, wide range, high resolution, convenient operation, convenient carrying, accuracy, reliability, stable performance and strong anti-interference ability. It is an indispensable instrument for battery production, battery installation, equipment production, equipment maintenance and other scenes. T-315 portable battery testers support the maintenance of UPS and storage batteries critical to the life support of all businesses. The T-315 battery internal resistance tester sets the standard for assessing the deterioration and remaining life of UPS and other lead-acid batteries by giving a complete diagnosis via battery resistance testing.
■ Check the battery health status;
■ Measurement the voltage of battery;
■ Measurement the temperature of battery;
■ Measurement the internal resistance of battery;
■ Support the maintenance of UPS and storage batteries;
■ Measurement the ESR parameters of electrolytic capacitor;
■ 7V/70V range;
■ With USB port;
■ Low power design;
■ Storage 5000 data logger;
■ 3mΩ/30mΩ/300mΩ/3Ω range;
■ High resolution 1uΩ and 1mV;
■ Built in batteries power supply;
■ Four wire method measurement;
■ Using noise reduction technology;
Electrical parameters | |
---|---|
Resistance measurement range | 3mΩ/30mΩ/300mΩ/3Ω |
Resolution | 1uΩ/10uΩ/100uΩ/1mΩ |
Accuracy | 1% |
Voltage measurement range | 7V/70V |
Resolution | 1mV/10mV |
Accuracy | 0.5% |
Temperature measurement range | -10.0℃~60.0℃ |
Resolution | 0.1℃ |
Accuracy | 0.1℃ |
Measurement method | Internal resistance measurement: 1kHz AC 4-terminal test method, open circuit terminal voltage 3V max Measuring current: 2.0ma ~ 200mA (different measuring currents in different ranges and gears) Temperature measurement: NTC temperature sensor (10K Ω at 26 ℃) A / D conversion mode: successive approximation type Display update frequency: 5 times / second |
Response time | 100ms |
Measurement time | about 2 seconds |
LCD dispaly | 70.1mm×52.6mm / 3.5 inches (320 * 240 resolution 16 bit TFT) |
Communication port | USB, Bluetooth |
Storage data | max 5000 sets |
Key | 10pcs |
Power supply | DC 3.7V rechargeable lithium battery |
Insulation resistance | above 20MΩ (500V between circuit and shell) |
Withstand voltage | AC 3700V / RMS (between circuit and shell) |
External magnetic field | <40A/m |
External electric field | <1V/m |
Consumption | 300mA MIN / 500mA MAX |
Standard | IEC 61010 |
Mechanical parameters | |
Dimensions (W×D×H) (mm) | 190×121×51 |
Weight (g) | 480 (with battery) |
Environmental conditions | |
Operating Temperature | -15°C to +55°C |
Storage Temperature | -20°C to +65°C |
Relative humidity | 0%-95% RH |