>Product>Current Probe>AC Current Clamp>1000a High Precision Economic Clamp On Current Probe
The round jaw design on the P50 Series clamp on current probes along with the high content nickel metal core makes them well suited for power quality applications where high accuracy and low phase shift along with wide frequency are important. Measurement range is 1mA to 1200A.
The P50 clamp current transformer is a general purpose 1000A AC current probe designed for use with DMMs, loggers and other instruments that have a current input. It has a 1000:1 ratio and output of 1mA per amp or 1mV per amp measured in the jaw. The P50 clamp current probe has an integral 2.5m lead terminated. The rounded jaw design on this probe makes it well-suited for power applications where high accuracy 0.1% and low phase shift and wide frequency response are important.
■ Multimeter;
■ Power meter;
■ Phase angle meter;
■ Energy sub-meters;
■ Cable fault analysis;
■ Large industrial loads;
■ Power load monitoring;
■ Earth resistance meter;
■ Data logging/recording;
■ Energy meter calibrator;
■ Power quality monitoring;
■ Power and harmonic meters;
■ Power quality analyzer(PQA);
■ CT secondary current detection;
■ Measuring around cable bundles;
■ Waveform analysis(oscilloscopes meter);
■ UL, CE mark;
■ Holding wire diameter: φ50mm;
■ Frequency 10Hz-2MHz Bandwidth;
■ High times harmonic measurement;
■ Conforms to EN 61010, 600V CAT III;
■ Measurement range of 1mA to 200A AC;
■ Low phase shift for power measurement;
■ High content nickel metal permalloy core;
■ Improved ergonomic design & easy operation;
■ High precision 0.1% for current measurement;
■ Designed for DMMs, recorders, loggers, oscilloscopes, power and harmonic meters;
Electrical parameters | |
---|---|
Ratio | 1000: 1 or 2000:1 (customized) |
Accuracy class | 0.1%, 0.2%, 0.5% |
Primary current | 0 - 1000A AC |
Secondary output | 1mV/A AC, 5mV/A or (customized) |
Secondary current | 0 - 1000mA AC and 0 - 5A AC |
Max. Cont. Input current | 1200A |
Load capacity | ≤20Ω , Standard 4Ω |
Over voltage category | CAT III 600V |
Output signal | 333mV, 500mV,1V,2V,5V AC at nominal input current |
Accuracy (1000A Range) | |
0-10A | ≤0.5% |
10-100 | ≤0.2% |
10-1200A | ≤0.1% |
Phase Shift(1000A Range) | |
0-10A | ≤0.5° |
10-100 | ≤0.2° |
100-1200A | ≤0.1° |
Frequency range | 40Hz-2000Hz or 10-2MHz |
Dielectric strength | 3KV 50Hz/60Hz at 1 minute |
Temperature range | -20°C to +55°C |
Output | 2.5 meter cable with D01 connector |
Max. voltage not insulated conductors | 600 V |
Standard | EN 61010-1, EN 61010-2-032, EN 61010-2-031 IEC60044-1, & IEC61869-2, 600V CAT III |
Installation | Clamp type |
Output mode | Lead output (2.5m) |
Connector | BNC, 4mm banana, signal cable(2 cores),customized |
Mechanical parameters | |
Dimensions (L x W x H) (mm) | 102.9 x 219.6 x 28 |
Weight (g) | 550 |
Holding wire diameter (mm) | φ50 |
Max. jaw opening (mm) | 50 |
Jaw color | Gray or blue |
Material | PC+ABS+Polycarbonate, UL94 V0 |
Model | Rate Current | Max Current | Secondary Current | Coil Ratio | Burden Resistance | Accuracy |
---|---|---|---|---|---|---|
P50-200 | 200A | 240A | 5A | 40:1 | 2.5VA | 0.5% |
P50-300 | 300A | 360A | 5A | 60:1 | 2.5VA | 0.5% |
P50-400 | 400A | 480A | 5A | 80:1 | 2.5VA | 0.5% |
P50-500 | 500A | 600A | 5A | 100:1 | 2.5VA | 0.5% |
P50-600 | 600A | 720A | 5A | 120:1 | 2.5VA | 0.5% |
P50-800 | 800A | 960A | 5A | 160:1 | 2.5VA | 0.5% |
P50-1000 | 1000A | 1200A | 5A | 200:1 | 2.5VA | 0.5% |
P501-100 | 100A | 120A | 1A | 100:1 | customized | 0.5% |
P501-200 | 200A | 240A | 1A | 200:1 | customized | 0.5% |
P501-300 | 300A | 360A | 1A | 300:1 | customized | 0.2% |
P501-400 | 400A | 480A | 1A | 400:1 | customized | 0.2% |
P501-500 | 500A | 600A | 1A | 500:1 | customized | 0.2% |
P501-600 | 600A | 720A | 1A | 600:1 | customized | 0.2% |
P501-800 | 800A | 960A | 1A | 800:1 | customized | 0.2% |
P501-1000 | 1000A | 1200A | 1A | 1000:1 | customized | 0.1% |
P502-500 | 500A | 600A | 500mA | 1000:1 | customized | 0.1% |
P502-1000 | 1000A | 1200A | 500mA | 2000:1 | customized | 0.1% |
P503-800 | 800A | 960A | 400mA | 2000:1 | customized | 0.1% |
P503-1000 | 1000A | 1200A | 400mA | 2500:1 | customized | 0.1% |
P504-500 | 500A | 600A | 250mA | 2000:1 | customized | 0.1% |
P504-1000 | 1000A | 1200A | 250mA | 4000:1 | customized | 0.1% |
Model | Rate Current | Max Current | Secondary Voltage | Coil Ratio | Burden Resistance | Accuracy |
P50V1-1000 | 1000A | 1200A | 1V | 1000:1 | customized | 0.1% |
P50V2-1000 | 1000A | 1200A | 2V | 1000:1 | customized | 0.1% |
P50V4-1000 | 1000A | 1200A | 4V | 1000:1 | customized | 0.1% |
P50V5-1000 | 1000A | 1200A | 5V | 1000:1 | customized | 0.1% |
P50V10-1000 | 1000A | 1200A | 10V | 1000:1 | customized | 0.1% |
P50V1-1000-2 | 1000A | 1200A | 1V | 1000:1 | customized | 0.2% |
P50V2-1000-2 | 1000A | 1200A | 2V | 1000:1 | customized | 0.2% |
P50V4-1000-2 | 1000A | 1200A | 4V | 1000:1 | customized | 0.2% |
P50V5-1000-2 | 1000A | 1200A | 5V | 1000:1 | customized | 0.2% |
P50V10-1000-2 | 1000A | 1200A | 10V | 1000:1 | customized | 0.2% |
P50V1-500 | 500A | 600A | 1V | 1000:1 | customized | 0.1% |
P50V2-500 | 500A | 600A | 2V | 1000:1 | customized | 0.1% |
P50V4-500 | 500A | 600A | 4V | 1000:1 | customized | 0.1% |
P50V5-500 | 500A | 600A | 5V | 1000:1 | customized | 0.1% |
P50V10-500 | 500A | 600A | 10V | 1000:1 | customized | 0.1% |
P50V1-500-2 | 500A | 600A | 1V | 1000:1 | customized | 0.2% |
P50V2-500-2 | 500A | 600A | 2V | 1000:1 | customized | 0.2% |
P50V4-500-2 | 500A | 600A | 4V | 1000:1 | customized | 0.2% |
P50V5-500-2 | 500A | 600A | 5V | 1000:1 | customized | 0.2% |
P50V10-500-2 | 500A | 600A | 10V | 1000:1 | customized | 0.2% |