The model Q125 2000A current transformer clamp on measuring instrument can be used for a current vector for the copper bar or the power aluminum bus bar on-line detection. It has a 120mm * 50mm square hole, make it specially suitable for bus bar current measurement. In this method, there is no need to break a circuit or to affect the isolation to measure the current. it can be applied for energy meter & power meter, Standard IEC61869 & CE. easy installation, measurement 3000A big current value.
■ HVAC;
■ Power meter;
■ Oscilloscopes;
■ Electrical utility;
■ Plant maintenance;
■ Electrical Laboratory;
■ Large industrial loads;
■ Data logging/recording;
■ Power quality analyzer;
■ Power load monitoring;
■ Industrial maintenance;
■ Power quality monitoring;
■ Power and harmonic meters;
■ Calibration instrument on site;
■ Energy meter calibrator on site;
■ Measuring around cable bundles;
■ Clamp type ground resistance tester;
■ UL, CE CNAS mark;
■ Frequency 40Hz-2000Hz Bandwidth;
■ Conforms to EN 61010, 600V CAT III;
■ Large bus bar jaw opening designed;
■ Measurement range of 1A to 3600A AC;
■ Holding wire diameter: φ120mm×50mm;
■ Low phase shift for power measurement;
■ Industrial design & beautiful appearance;
■ Transformation ratio: 1000:5, 2000:5, 3000:5
■ High precision 0.2% for current measurement;
■ Improved ergonomic design & easy operation;
■ Output:5mA AC/A AC, 2.5mA AC/A AC, 1.666mA AC/A AC
■ Nominal range: 1 to 1000AAC, 1 to 2000AAC, 1 to 3000AAC
■ When less than 1A output, load capacity ≤20Ω; When 5A output, load 2.5VA;
■ Designed for recorders, loggers, oscilloscopes, power and harmonic meters;
Electrical parameters | |
---|---|
Ratio | 1000: 1 or 2000:1 (customized) |
Accuracy class | 0.2%, 0.5%, 1% |
Primary current | 0 - 3000A AC |
Secondary current | 0 - 5A AC (customized) |
Max. Cont. Input current | 3600A |
Over voltage category | CAT III 600 V |
Output signal (AC current) | 500mA,1A,5A AC at nominal input current |
Output signal (AC voltage) | 333mV,500mV,1V,5V AC at nominal input current |
Frequency range | 40Hz-2000Hz |
Dielectric strength | 3KV 50Hz/60Hz at 1 minute |
Temperature range | -20°C to +55°C |
Output | 2.5 meter cable with D01 connector |
Max. voltage not insulated conductors | 720 V |
Standard | EN 61010-1, EN 61010-2-032, EN 61010-2-031 IEC60044-1, & IEC61869-2, 600V CAT III |
Installation | Clamp type |
Output mode | Lead output (2.5m) |
Connector | BNC, 4mm banana, signal cable(2 cores),customized |
Mechanical parameters | |
Dimensions (L x W x H) (mm) | 116 x 327 x 35 |
Weight (g) | 1200 |
Holding wire diameter (mm) | φ120 x 50 |
Max. jaw opening (mm) | 50 |
Jaw color | White or Blue |
Material | PC+ABS, UL94 V0 |
Model | Rate Current | Max Current | Secondary | Coil Ratio | Burden Resistance | Accuracy |
---|---|---|---|---|---|---|
Q125A5-500 | 500A | 600A | 5A | 100:1 | 2.5VA | 0.5% |
Q125A5-600 | 600A | 720A | 5A | 120:1 | 2.5VA | 0.5% |
Q125A5-800 | 800A | 960A | 5A | 160:1 | 2.5VA | 0.5% |
Q125A5-1000 | 1000A | 1200A | 5A | 200:1 | 2.5VA | 0.5% |
Q125A5-2000 | 2000A | 2400A | 5A | 400:1 | 2.5VA | 0.5% |
Q125A5-3000 | 3000A | 3600A | 5A | 600:1 | 2.5VA | 0.5% |
Q125A1-1000 | 1000A | 1200A | 1A | 1000:1 | 2.5VA | 0.2% |
Q125A1-2000 | 2000A | 2400A | 1A | 2000:1 | 2.5VA | 0.2% |
Q125A1-3000 | 3000A | 3600A | 1A | 3000:1 | 2.5VA | 0.2% |
Q125A2-500 | 500A | 600A | 250mA | 2000:1 | customized | 0.2% |
Q125A2-1000 | 1000A | 1200A | 500mA | 2000:1 | customized | 0.2% |
Q125A2-2000 | 2000A | 2400A | 500mA | 4000:1 | customized | 0.2% |
Q125A3-1000 | 1000A | 1200A | 400mA | 2500:1 | customized | 0.2% |
Q125A3-2000 | 2000A | 2400A | 400mA | 5000:1 | customized | 0.2% |
Q125A4-1000 | 1000A | 1200A | 250mA | 4000:1 | customized | 0.2% |
Notes: Can be customized current probe according to user requirements! |