>Product>Electrical Test Equipment>Electrical Test Tool>Clamp Power Data Logger
GF112R clamp on power data logger is a high precision industrial clamp on power meter in accuracy class 0.2, used for testing all electrical parameter-voltage, current, active power, reactive power, apparent power, harmonics, phase angle, power factor, frequency, energy etc on site. Wide measurement range from up to 600A and 600V, 2-31st harmonics measurement, clamp type industrial design, with 3.5 inch touch TFT color LCD, bluetooth and USB. GF112R have become popular tools primarily for field electrical engineer.
■ Factory;
■ Power plant;
■ Electrical laboratory;
■ Metrological service center;
■ Power engineering company;
■ Distribution power corporation;
■ Power quality check department;
■ Oil, gas, petrochemical company;
■ Electricity power bureau & power company;
■ Electrical department of industrial and mining enterprises;
■ Power accuracy class 0.2;
■ Display of vector diagram;
■ 3.5 inch color touch TFT LCD;
■ Low power design technology;
■ 2-31st harmonics measurement;
■ Easy and user friendly operation;
■ Storage 5000 groups calibrate data;
■ With APP software, export test report;
■ Lithium batteries/3AAA can be replaced;
■ Recorder data can be download by U disk;
■ With bluetooth & USB communication port;
■ Automatic compensation for current clamp;
■ Unique long-term and temperature stability;
■ Measure U, I, P, Q, S, E, PF, frequency etc;
■ Recorder all kinds of electrical parameters;
■ Wide measuring range 0-600V/0.001-600A;
■ Recorder time interval from 1s to 60 minutes;
■ The Li-battery can work 48 hours continuously;
■ One screen displays all the measured parameters;
■ Oscilloscope function display current & current wave;
■ The meter and current clamp have Integration design;
Electrical parameters | |
---|---|
Accuracy class | 0.2% |
Power supply | AAA type, 3PCS, Li rechargeable battery, 2700mAh, 3.6V it can work 48 hours continuously |
Warming-up time | <2min |
Voltage measurement | |
U range | 0-700V |
Accuracy | 0.1% |
Harmonics | 2nd-31st |
Current measurement | |
I range | 1mA-120A or 0mA-600A |
Accuracy | 0.2% |
Harmonics | 2nd-31st |
Phase measurement | |
Range | 0.00°-359.99° |
Resolution | 0.01° |
Accuracy | 0.05° |
Power measurement | |
Range | 0-72KV or 0-360kW |
Accuracy | 0.2% |
Frequency measurement | |
Range | 40-70Hz |
Resolution | 0.001Hz |
Accuracy | 0.002Hz |
Power factor measurement | |
Range | -1~0~1 |
Resolution | 0.0001 |
Accuracy | 0.0002 |
Harmonics | |
Harmonics order | 2-31 times |
Harmonics content | Yes, 0-100% |
Harmonics bar graph | Yes |
Function | |
Key | 2pcs (hold, power) |
PC management software | Yes |
Android app | Optional |
LCD | 3.5 inch touch TFT color LCD |
RMS | Yes |
Waveform measurement | Yes |
Recorder parameter | U, I, P, Q, S, F, PF, phase angle |
Recorder time interval setting | 1s-60minutes |
Data storage | 5000 sets |
Communication port | USB & bluetooth port |
Standard | |
Standard | IEC61010-1, IEC61010-2-32 CAT III 600V/CAT IV 300V, IEC61010-2-31, IEC60529, pollution grade 2, EN/IEC 61326, IEC61000-4-30, IEC61000-4-7, IEEE 519, IEC61000-4-15, IEEE 1459, EN 50160 |
Safety | |
Isolation protection | IEC 61010-1:2001 |
Measurement category | 600V CAT IV |
Degree of protection | IP50 |
Declaration of conformity | CE & CNAS certified |
Mechanical parameters | |
Dimensions (W×D×H)(mm) | 225×61×38, 235×61×38 Aperture of current clamp: 30mm or 50mm |
Weight (kg) | 0.35 or 0.5 (mains) 1 or 1.5 (accessory and box) |
Environmental conditions | |
Working temperature | -10°C to 55°C |
Working humidity | 5%-85% RHD |
Storage temperature | -25°C to 70°C |
Storage humidity | 5%-95%RHD |