HV hipot test set
HV hipot test set

T-100KVPORTABLE HV HIPOT TEST SET

T-100KV HV Hipot test set is the effective and direct way to test insulation strength for electric equipment,apparatus or machines.It checks dangerous flaws which assure electric equipment continuous working.This model T-100KV HV Hipot test set can output up to 100KV AC and 140KV DC, 100mA ac current output capacity, suite ofr many electrical equipment testing. Typical applications include testing of transformers, switchgears, cables, capacitors,aerial motors platforms,hot sticks bucket bricks,vacuum bottles and other related equipment like vacuum interrupters, blankets, ropes,gloves,hydraulics hose,instruments transformers generators.

APPLICATION

■ Fuses; ■ Coils; ■ Bushings; ■ Connectors; ■ Insulators; ■ Power Cables; ■ HV Components; ■ Circuit Breakers; ■ Power Capacitors; ■ Lightning arresters; ■ Cable Joints/Splices; ■ Instrument Transformers; ■ Switchgear (Air, Gas, Oil); ■ Transformers, Shunt Reactors; ■ Insulation Materials (Oil, Paper); ■ High voltage distribution cabinet;

FUNCTION & FEATURES

■ Voltage accuracy 1%;

■ 0-100KV AC/DC output;

■ Load power capacity 10KVA;

■ Light weight,small size,easy to move;

■ Continuously variable output from zero to full voltage;

■ Using the latest current relay, more accurate and reliable;

■ With new type time relay,time rang is more wider (1S ~ 99H);

■ Over-current protection,zero-starting protection,sound and light alarm;

■ Adjustable over current protection,with trip levels variable from 10 to 110%;

■ Digital display panel mounted controls & indicators with easy to read legend;

■ Monitoring high voltage side voltage,low voltage side current and indicator of zero, power, working start, timer;

PARAMETERS

Electrical parameters
Power supply AC 230V±10% or 380V±10%, 50/60HzAC
AC Voltage output 0-100KV
DC Voltage output 0-140KV
AC current output 100mA
DC current output 70mA
Accuracy 1%
Capacity 10KVA, customized (1kVA-100KVA)
Frequency 50Hz / 60Hz
Adjustment component Voltage regulator
Display model of Voltage Digital meter
Accuracy class of the voltage meter 0.2%
Adjustment model Manual or Auto
Timer range 0.01S-99.99H
Protection function Over-current
Cooling model Self-cooled
Testing Transformer Oil, dry, SF6 gas optional
Output voltage of control unit AC 0-250V or 0-430V
Standard GB/T15290, GB/T8554, GB/T16927, DL/T848, DL/T846, IEC61007, IEC60060, IEC60270, IEC 60243-1, ASTM D149
Mechanical parameters
Dimension (L×W×H) (mm) 650x600x750, 450x500x650
Weight (kg) 125+54
Environmental conditions
Operating Temperature -20°C to 50°C
Storage Temperature -40°C to 70°C
Relative humidity ≤85%RH