>product>Energy Meter Parts>HIGH ACCURACY 0.1% 20Ω 100A MINIATURE CURRENT TRANSFORMER FOR ENERGY METER

FU-CT-O_gfuve_0.1%_miniature_current_transformer
FU-CT-O_gfuve_0.1%_miniature_current_transformer

FU-CT-OHIGH ACCURACY 0.1% 20Ω 100A MINIATURE CURRENT TRANSFORMER FOR ENERGY METER

This specification suitable for 50/60Hz multifunctional electronic electric energy meter, anti-stealing electric meter, digital meter, also be used for transducer electric variables, remote control data acquisition system, relay protection, digital device and meters.
All of our miniature current transformers are strictly comply IEC60044-1, IEC 61869-2, ANSI/IEEE C57.13, GB1208-2006, GB/T 20840.1-2010, GB/T 20840.2-2014, GB/T 22071.1-2018, IEC/EN61010-2-032, IEC/EN 61010-2-031.

FEATURES

■ Measurement range of 1mA to 120A AC;

■ Low phase shift for power measurement;

■ High precision 0.1% for current measurement;

■ Holding wire diameter: φ5mm, 8mm, 13mm, 20mm;

■ Harmonic measurement;

■ High accuracy, wide linear range, good consistency;

■ Improved ergonomic design & easy operation;

■ High content permalloy core;

■ Multiple appearances can be choosed;

■ IEC/EN61010-2-032, IEC 60044-1, IEC 61869-2 etc standard;

■ Suitable for three-phase electric energy meters with high precision and small phase displacement;

■ Wide linear output current, high precision and good consistency;

■ Encapsulated with epoxy resin, power-frequency withstand voltages: 4000V 50Hz/1min, insulation resistance: ≥1000MΩ/500Vdc;

■ Working frequency: 50Hz~400Hz;

■ Operating temperature: -40℃~95℃;

■ Comply to IEC 60044-1 0.05 class, class 0.1, class 0.2 standard requirements;

■ DC and even harmonics:100A/√2, 1inductive, error should be less than ±3%@PF=1.0;

APPLIATIONS

■ Three-phase electric energy meters;

■ Anti-stealing electric meter;

■ Digital meter;

■ Transducer electric variables;

■ Remote control data acquisition system;

■ Relay protection;

■ Digital devices and meters;

■ Metering device.

PARAMETERS

Current error( ratio )±% Phase error ( angle )±'
Rated current percent value Rated current percent value
5% 20% 100% Imax 5% 20% 100% Imax
-0.1~+0.1 -0.1~+0.1 -0.1~+0.1 -0.1~+0.1 -15~+15 -13~+13 -10~+10 -8~+8
Note: All the above data need to be measured after demagnetization

SELECTION GUIDE

Model Rated Primary Current Current Ratio Rated Burden Accuracy Class
FU-CT-O001 5A-320A 3000∶1 10Ω 20Ω 0.1
FU-CT-O002 5A-100A 2500∶1 10Ω 20Ω 0.1
FU-CT-O003 5A-120A 2500∶1 10Ω 20Ω 0.2
FU-CT-O004 5A-60A 2500∶1 10Ω 20Ω 0.1
FU-CT-O005 1A-90A 3100∶1 10Ω 20Ω 0.1
FU-CT-O006 5A-100A 4000∶1 10Ω 20Ω 0.1
FU-CT-O007 5A-100A 2000∶1 10Ω 20Ω 0.1
FU-CT-O008 5A-100A 1000∶1 10Ω 20Ω 0.1
FU-CT-O009 5A-80A 2500∶1 10Ω 20Ω 0.1
FU-CT-O010 5A-60A 2000∶1 10Ω 20Ω 0.1
FU-CT-O011 5A-100A 2000∶1 10Ω 20Ω 0.1
FU-CT-O012 5A-60A 1000∶1 10Ω 20Ω 0.2
FU-CT-O013 5A-200A 4000∶1 10Ω 20Ω 0.1
FU-CT-O014 5A-100A 2500∶1 10Ω 20Ω 0.1
FU-CT-O015 5A-60A 2500∶1 10Ω 20Ω 0.1
FU-CT-O016 5A-100A 2500∶1 10Ω 20Ω 0.1
FU-CT-O017 5A-60A 2500∶1 10Ω 20Ω 0.1
FU-CT-O018 5A-400A 4000∶1 10Ω 20Ω 0.1
FU-CT-O019 5A-100A 2500∶1 10Ω 20Ω 0.1
FU-CT-O020 5A-100A 2500∶1 10Ω 20Ω 0.1
Notes: Only few typical products of this series are shown in the following page. GFUVE is capable of making other customized design and manufacturing per user request.