>product>Energy Meter Parts>0.1% 20ω Miniature Multiple Phase Current Transformer

FU-CT-Z_20Ω_multiple_phase_current_transformer
FU-CT-Z_20Ω_multiple_phase_current_transformer

FU-CT-Z0.1% 20Ω MINIATURE MULTIPLE PHASE CURRENT TRANSFORMER

FU-CT-Z series multiple phase current transformers are high precision small current transformers, they are in delicate aesthetic appearance, flexible structure, small volume and light weight, the insulating ability is strong, earthquake prevention which are suitable for three-phase electric energy meters with high precision and small phase displacement.
This specification suitable for 50/60Hz multifunctional electronic electric energy meter, anti-stealing electric meter, digital meter, also be used for transducer electric variables, remote control data acquisition system, relay protection, digital device and meters.
All of our miniature current transformers are strictly comply IEC60044-1, IEC 61869-2, ANSI/IEEE C57.13, GB1208-2006, GB/T 20840.1-2010, GB/T 20840.2-2014, GB/T 22071.1-2018, IEC/EN61010-2-032, IEC/EN 61010-2-031.

FEATURES

■ Measurement range of 1mA to 100A AC;

■ Low phase shift for power measurement;

■ High precision 0.1% for current measurement;

■ Holding wire diameter: φ5mm, 8mm, 13mm, 20mm;

■ Multiple phase design;

■ Harmonic measurement;

■ Multiple appearances can be choosed;

■ Improved ergonomic design & easy operation;

■ High content permalloy core;

■ IEC/EN61010-2-032, IEC 60044-1, IEC 61869-2 etc standard;

■ High accuracy, wide linear range, good consistency;

■ Suitable for three-phase electric energy meters with high precision and small phase displacement;

■ Wide linear output current, high precision and good consistency;

■ Encapsulated with epoxy resin, power-frequency withstand Voltages: 4000V 50Hz/1min, Insulation Resistance: ≥1000MΩ/500Vdc;

■ Working frequency: 50Hz~400Hz;

■ Operating Temperature: -40℃~95℃;

■ Comply to IEC 60044-1 0.05 class, class 0.1, class 0.2 standard requirements;

■ DC and even harmonics: 100A/√2, 1inductive, error should be less than ±3%@PF=1.0;

APPLIATIONS

■ Three-phase electric energy meters;

■ Anti-stealing electric meter;

■ Digital meter;

■ Transducer electric variables;

■ Remote control data acquisition system;

■ Relay protection;

■ Digital devices and meters;

■ Metering device.

PARAMETERS

Current error(ratio)±% Phase error (angle)±'
Rated current percent value Rated current percent value
5% 20% 100% Imax 5% 20% 100% Imax
-0.1~+0.1 -0.1~+0.1 -0.1~+0.1 -0.1~+0.1 -15~+15 -13~+13 -10~+10 -8~+8
Note: All the above data need to be measured after demagnetization

SELECTION GUIDE

Model Rated Primary Current Current Ratio Rated Burden Accuracy Class
FU-CT-Z001 5A~60A 2500∶1 20Ω 0.1
FU-CT-Z002 5A~80A 2500∶1 20Ω 0.1
FU-CT-Z003 5A~100A 2500∶1 25Ω 0.1
FU-CT-Z004 1A~6A 1800∶1 20Ω 0.05
FU-CT-Z005 1A~9A 1500∶1 20Ω 0.1
FU-CT-Z006 5A~100A 5000∶1 20Ω 0.1
FU-CT-Z007 5A~100A 5000∶1 20Ω 0.1
FU-CT-Z008 5A~100A 5000∶1 20Ω 0.1
FU-CT-Z009 1A~10A 1500∶1 20Ω 0.1
FU-CT-Z010 1A~10A 1600∶1 20Ω 0.1
FU-CT-Z011 1A~10A 1500∶1 20Ω 0.1
Notes: Only few typical products of this series are shown in the following page. GFUVE is capable of making other customized design and manufacturing per user request.