Q150SPLIT CORE 150MM 3000/5A CURRENT TRANSFORMER CLAMP

The model Q150 current transformer clamp can be used in large current situation and cooperate to cable fault tester and cable identification device, used for cable test work. It can even measure up to 3000A AC large current and output 0-5A AC current for other measuring or analyzing system. It can provide 0.5% accuracy class result, ratio 1000/5A, 2000/5A or 3000/5A. Suitable for power plants, factoris and mines to measure power load.

APPLICATION

■ HVAC;

■ Power meter;

■ Energy meter;

■ Oscilloscopes;

■ Electrical utility;

■ Cable fault tester;

■ Plant maintenance;

■ Electrical Laboratory;

■ Large industrial loads;

■ Power load monitoring;

■ Data logging/recording;

■ Power quality analyzer;

■ Industrial maintenance;

■ Power quality monitoring;

■ Power and harmonic meters;

■ Measuring around cable bundles;

■ Clamp type ground resistance tester;

■ Electric energy meter calibrator on site;

FEATURES

■ UL, CE CNAS mark;

■ Large jaw opening designed;

■ Holding wire diameter: φ150mm;

■ Frequency 40Hz-2000Hz Bandwidth;

■ Conforms to EN 61010, 600V CAT III;

■ Measurement range of 1A to 3600A AC;

■ Low phase shift for power measurement;

■ Precision 0.5% for current measurement;

■ Industrial design & beautiful appearance;

■ Transformation ratio: 1000:5, 2000:5, 3000:5

■ Improved ergonomic design & easy operation;

■ Output:5mA AC/A AC, 2.5mA AC/A AC, 1.666mA AC/A AC;

■ Nominal range: 1 to 1000AAC, 1 to 2000AAC, 1 to 3000A AC;

■ When less than 1A output, load capacity ≤20Ω; When 5A output, load 2.5VA;

■ Designed for cable fault analysis, recorders, loggers, power and harmonic meters;

PARAMETERS

Electrical parameters
Ratio 600: 1 , 1000:1, 2000:1, 3000:1 (customized)
Accuracy class 0.2%, 0.5%, 1%
Primary current 0 - 3000A AC
Secondary current 0 - 5A AC (customized)
Max. Cont. Input current 3600A
Load capacity ≤2.5VA or 20Ω
Over voltage category CAT III 600 V
Output signal (AC current) 500mA,1A,5A AC at nominal input current
Output signal (AC voltage) 333mV,500mV,1V,5V AC at nominal input current
Frequency range 40Hz-2000Hz
Dielectric strength 3KV 50Hz/60Hz at 1 minute
Temperature range -20°C to +55°C
Output 2.5 meter cable with D01 connector
Max. voltage not insulated conductors 720 V
Standard EN 61010-1, EN 61010-2-032, EN 61010-2-031
IEC60044-1, & IEC61869-2, 600V CAT III
Installation Clamp type
Output mode Lead output (2.5m)
Connector BNC, 4mm banana, signal cable(2 cores),customized
Mechanical parameters
Dimensions (L x W x H) (mm) 229x364x 44
Weight (g) 1700
Holding wire diameter (mm) φ150
Max. jaw opening (mm) 150
Jaw color White
Material PC+ABS, UL94 V0

SELECTION GUIDE

Model Rate Current Max Current Secondary Coil Ratio Burden Resistance Accuracy
Q150A5-1000 1000A 1200A 5A 200:1 2.5VA 0.5%
Q150A5-2000 2000A 2400A 5A 400:1 2.5VA 0.5%
Q150A5-3000 3000A 3600A 5A 600:1 2.5VA 0.5%
Q150A1-1000 1000A 1200A 1A 1000:1 2.5VA 0.5%
Q150A1-2000 2000A 2400A 1A 2000:1 2.5VA 0.5%
Q150A1-3000 3000A 3600A 1A 3000:1 2.5VA 0.5%
Q150A2-500 500A 600A 250mA 2000:1 customized 0.5%
Q150A2-1000 1000A 1200A 500mA 2000:1 customized 0.5%
Q150A3-500 500A 600A 200mA 2500:1 customized 0.5%
Q150A3-1000 1000A 1200A 400mA 2500:1 customized 0.5%
Q150A3-2000 2000A 2400A 800mA 2500:1 customized 0.5%
Q150A4-250 250A 300A 250mA 1000:1 customized 0.5%
Q150A4-500 500A 600A 500mA 1000:1 customized 0.5%
Q150A4-1000 1000A 1200A 250mA 4000:1 customized 0.5%
Q150A4-2000 2000A 2400A 500mA 4000:1 customized 0.5%
Notes: Can be customized current probe according to user requirements!