>Product>Power Meter>Ethernet Power Meter>Multifunction Electrical Digital Power & Energy Meter Rs485
FU2000 digital power & energy meter is a multifunction electrical digital power & energy meter, it can measure all the electrical parameters in the power line, and it has RTC, calendar and one pulse output, one RS485, with modbus RTU communication. As an advanced smart and digital front end data sampling unit, the FU2000 electrical digital power meters can be used in various control system, industrial automation, smart buildings, energy management system, substation automation, residential power monitoring, smart distributor and switch gears. They are easy to install, connect, maintain. They need less project cost and field programming on spot for power grid grouping with different PLC and industrial control PC communication software.
■ Airport;
■ Power plant;
■ Data logging;
■ Energy meter;
■ Intelligent building;
■ Power quality analysis;
■ Data transmission center;
■ Power monitoring system;
■ Photovoltaic power station;
■ Commercial, industrial, utility;
■ Mobile communication company;
■ Medium and low voltage systems;
■ Electric energy metering cabinet;
■ Low voltage distribution cabinet;
■ Industrial and mining enterprises;
■ High voltage distribution cabinet;
■ Energy consumption monitoring system;
■ Metering of capacitor banks and motors;
■ Electric energy metering of photovoltaic power station;
■ Metering of distribution feeders, transformers, generators;
■ Energy pulse output;
■ It has RTC, calendar;
■ 4-line LCD with backlight;
■ Multifunction power meter;
■ Accuracy class can reach 0.5;
■ Modbus-RTU communications;
■ Direct voltage input up to 600V / AC;
■ Measure all the electrical parameters;
■ The kWh meter data can be reset by password;
■ After power supply failure, the setting parameters are not lost;
■ 120×120mm panel installation, 92×92mm trepanning dimension;
■ active energy metering and positive and negative reactive energy metering;
■ Directly display primary measured value, and programmable PT/ CT ratio arbitrarily;
■ There are six wiring modes: 3P4W, 3P4W balance, 3P3W, 3P3W balance, 1P2W and 1P3W;
■ easure phase voltage, line voltage, current, power, power factor, frequency, positive and negative
Electrical parameters | |
---|---|
Power supply (AC/DC) | AC 85-265V/DC 85-330V, DC18-90V (option) Power Consumption: <4VA |
Measurement parameters | Voltage (Ph-N); Voltage (Ph-Ph); Current; Frequency; PF; Active Power (W); Reactive Power (Q); Apparent Power(S) |
Computation | Forward active power energy Reverse active power energy Forward reactive power energy Reverse reactive power energy |
Measuring range | 30-600V, 0-6A, 45-65Hz, -1 ~ 0 ~ 1 |
Measuring accuracy | Frequency: 0.1% Electric energy: 0.5%, 1.0% Voltage : 0.2%±0.1V Current : 0.2%±0.001A Power : 0.5% ±0.4W Power Factor : 0.5% ±0.001 |
Display | LCD Display, 128X64 Lattice, English and Chinese interface, 4 Displays. Green back-lit 4 operation keys. |
Communication | RS-485 interface port support, 32(128) Networking, ModBus-RTU communication protocol. |
Programmable | Measuring system: 3P4W/3P3W etc. Transformation ratio: PT, CT Communication: Address: 1-247; Baud: 1200-19200; Parity Bit: N/E/O RTC: year; month; day; hour; minute; second Energy: reset |
Energy pulse (optional) | One active energy pulse output Pulse constant: 5000kWh Photocoupler output (0.1Ax30V) |
Connection mode | 3P4W, 3P4W BAL, 3P3W, 3P3W BAL, 1P2W, 1P3W |
RTC | Accuracy drift less than 2.5min/year |
Standard | EN610101:2010; EN61010-2-030:2010; EN61326-1:2013; EN61000-3-2:2014; EN61000-3-3:2013; IEC61000-4; IEC61557-12; IEC60068-2-1/2/30 IEC 62052-11; IEC 62053-21; IEC 62053-22 |
Mechanical parameters | |
Dimensions (L x W x H) (mm) | Mounting Panel: 120x120 Thickness: 21 Depth: 118 |
Mounting | Panel mounting Trepanning: 92x92mm |
Environmental conditions | |
Temperature | -25 to +55°C |
Humidity | 20%-95%RH, without condensation |