>Product>Electrical Test Equipment>EV & Recharging Testing>Portable Ac Ev Charger Testing Equipment With 9kw Load
GF1115B AC EV charger testing equipment can achieve metrological verification, operation and maintenance error verification, start stop and other tests of AC charging piles. It can simultaneously measure the output voltage, current, power, electrical energy, harmonics, phase, frequency, waveform distortion rate and clock error of charging piles. At the same time, it also has functions such as insulation resistance testing, temperature acquisition, humidity acquisition, GPS time calibration, etc. The entire process can be automated and manually tested. Large screen English menu display, with a large amount of information displayed and easy operation. Technically, GF1115 uses various cutting-edge technologies to achieve high performance, such as 24bit high-speed and high-precision synchronous sampling AD and 500M dual core DSP CPU.
■ With 9KW AC load;
■ Meet CCS2 Europe port;
■ As a waveform recorder;
■ Wide range 0-480V/0-63A;
■ With PC software optional;
■ Waveform display function;
■ Energy accumulating function;
■ Measuring 2nd~127th harmonics;
■ High accuracy class up to 0.05%;
■ High stability, high reliability;
■ Automatic and manual test optional;
■ Using 24bit AD sampling technology;
■ Automatic generation of test report;
■ Metal structure, strong and reliable;
■ With Li-battery, working more than 8 hours;
■ Portable, small size, drag bar box structure design;
■ Suit for testing EV & Charging AC pile error on site;
■ Built in WIFI, it can be controlled by PDA, PC computer;
■ According to JJG 1148-2022 & GB/T 34657.1-2017 Standard;
■ Safety test, performance test, Compatibility test, Metrological test;
■ Integrated design concept, built-in reference meter, insulation resistance tester, oscilloscope, interface simulator, power analyzer etc;
■ CC interrupt test;
■ CP grounding test;
■ CP interrupt test;
■ Output overcurrent test;
■ Charging readiness test;
■ JJG 1148-2022 Standard;
■ Normal charging end test;
■ Disconnect switch S2 test;
■ Testing of working error;
■ CP loop voltage limit test;
■ Display error verification;
■ Insulation resistance test;
■ GB/T 34657.1-2017 Standard;
■ Connection confirmation test;
■ Start up and charging phase test;
■ Testing of payment amount error;
■ Testing of clock indication error;
■ Temperature and humidity detection;
■ Charging connection control sequence test;
■ Continuity loss test of protective grounding conductor;
■ Electrical laboratory; ■ EV & Charging pile factory; ■ Metrological service center; ■ Laboratories of power utilities; ■ Third party testing organization; ■ Electricity power bureau & power company; ■ National Metrology and testing department; ■ Charging pile operation and maintenance organization;
Electrical parameters | |
---|---|
Accuracy class | 0.05% |
Power supply | One phase AC 100-265V, frequency 50/60Hz; Li-battery |
Warming-up time | <75VA |
Voltage measurement | |
Range | 380V (0-480.000V) |
Error | ±0.02% (30V-480V) |
Harmonic | 2nd-127nd |
Current Measurement | |
Range | 63A (0-80.000A) |
Error | ±0.02% (1A-80A) |
Harmonic | 2nd-127nd |
Power measurement error | |
Active power | ±0.05% (1A-80A,30-480V) |
Energy measurement error | |
Active energy | ±0.05% (50%-120%Un)/(1%-110%In) |
Phase angle | |
Range | 0°-360.000° |
Resolution | 0.01° |
Error | ±0.05° |
Power factor | |
Range | -1.00000-0-1.00000 |
Resolution | 0.00005 |
Error | 0.00001 |
Frequency | |
Range | 45.0000-65.0000Hz |
Resolution | 0.001 |
Error | ±0.005 |
Pulse output | |
Output channel | 1 |
Energy constant | 1-9999999 |
Pulse ratio | 1:1 |
Output level | 5V |
Output rated frequency | 0-100KHz |
Pulse input | |
Input channel | 1 |
Input level | 3-12V |
Input frequency | 0-100KHz |
Insulation Resistance Measurement | |
Voltage Range | 0-1000V |
Resistance range | 0-50MΩ |
Accuracy | ±5% (1~50MΩ) |
Power Analyzer (AC) | |
AC voltage input (L1\L2\L3\N) | 220V±20% (±0.05%RD) |
AC current input (IL1\IL2\IL3) | 0.1-500A(±0.5%RG) (current sensor optional) |
Accuracy | ±0.5% |
Voltage harmonic times | 2-127 times |
Current harmonic times | 2-127 times |
Wave Recorder Measurement | |
Voltage input range | 0-±1000V |
Accuracy | ±1%RG |
Waveform capture resolution | 10us |
CAN baud rate | 250kbit/s |
Temperature Measurement | |
Range | -40°C to +80°C |
Accuracy | ±0.3°C |
Resolution | 0.1°C |
Humidity Measurement | |
Range | 0%RH-99.99%RH |
Accuracy | ±5%RH |
Resolution | 0.1%RH |
Load | |
Range | 0-9KW |
Min step | 0.01kW/ 200V |
Gear numbers | 8192 |
Function | |
LCD Display | 10 inch 800×600 touch TFT |
Energy accumulation | Yes |
Self-calibration | Yes |
Data storage | Yes |
Auto test | Yes |
Manu test | Yes |
GPS | Yes |
Test report (word file) download | Yes |
PC software | Optional |
Communication port | RS232, USB, WIFI, 10/100M LAN |
Standard | |
Standard | IEC 62053-21, 22, 23; IEC 60736; ANSI C12.20-2002; IEC 62196-2; IEC 62196-3;JJG 597-2005; JJG596-2012; JJG 1085-2013; JJG 1148-2022; GB/T 34657.1-2017; JJF 68-2019; DL/T 826-2002; DL/T 1478-2015; DL/T 448-2016; |
Safety | |
Isolation protection | IEC 61010-1:2001 |
Measurement Category | 300V CAT III, 600V CAT II |
Degree of protection | IP65 |
Declaration of conformity | CE & CNAS certified |
Mechanical parameters | |
Dimension (L×W×H)(mm) | 365×212×532 |
Weight (kg) | 12 |
Environmental conditions | |
Ambient temperature | -20°C to +50°C |
Storage temperature | -30°C to +65°C |
Relative humidity | 10%-85% |
Temperature coefficient | ≤0.005%/°C |
Influence of external fields | ≤0.05%/mT |