>Product>CT & PT>Instrument Current Transformer>Epoxy Resin Indoor High Accuracy 33kv Current Transformer

indoor current transformer
indoor current transformer

GFLZZ0757-35QEPOXY RESIN INDOOR HIGH ACCURACY 33KV CURRENT TRANSFORMER

This model GFLZZ0757-35Q indoor post type current transformer is used in 36KV, 35KV, 33KV, 27KV, 25KV power system, for measuring and protection. It has been used in outdoor pole mounted and transmission line. This product has the characteristics of high efficiency and large capacity, and can be customized according to customer requirements.

DESCRIPTIONFor insulation and protection, the assembly is cast in hydrophobic cycloaliphatic epoxy (HCEP) using automatic vacuum pressure. The HCEP material offers superior arc track, ozone, and ultraviolet-resistive properties while maintaining physical strength. Primary and secondary use pure electrolytic copper, both winding and core have high voltage shielding processing. The hydrophobic surface properties of HCEP ensure highly reliable performance in wet, humid, or polluted environments. It can be used for 33KV distribution line, coal mine, power plant, Rail way, factories.. . The dry type instrument current transformers are strictly in conformity with IEC60044, IEC 61869, ANSI/IEEE C57.13, NBR6855 etc.

APPLICATION

■ Rail way;

■ Coal Mine;

■ Power plant;

■ Power Meter;

■ Energy meter;

■ Power station;

■ Oil, gas company;

■ Distribution system;

■ Measuring instrument;

■ Electric Power Bureau;

■ Primary metering cabinets;

■ MV Power Quality Analyzer;

■ Substation metering and relaying;

■ Industrial and mining enterprises;

FEATURES

■ Weight: 80KG;

■ Using life: 30 years;

■ Post type outdoor design;

■ Rated voltages up to 36 kV;

■ Secondary current output 5A or 1A;

■ Compact size & mounting flexibility;

■ Tin plated copper primary terminals;

■ 36KV, 35KV, 33KV, 27KV, 25KV Outdoor;

■ Reasonable structure and robust construction;

■ Surface creepage distance more than 1300mm;

■ Material:Epoxy(HCEP) + outdoor silicone cover;

■ Rated basic insulation levels (BIL) up to 200 kV;

■ Built-in surge protection for current transformers;

■ Environmentally friendly & minimum maintenance;

■ Standard & Special High Accuracy metering classes;

■ Convenient installation, suitable for installation in any location;

■ Accuracy class: 0.2S 0.2, 0.5S, 0.5, 1, 5P20, 5P10, 10P20, 10P15;

■ IEC60044-1, IEC 61869-2, GB/T 20840.1,2 & ANSI/IEEE C57.13 Standards;

PARAMETERS

Technical parameters
Standards IEC60044; IEC 61869; ANSI/IEEE C57.13, GB/T 20840.1,2
Accuracy Class 0.2s, 0.2, 0.5s, 0.5, 1, 10P10, 10P15, 5P20, 5P10
Rated Voltage 36KV, 35KV, 33KV, 27KV, 25KV
Rated primary current 20-2000A
Rated load ≤25VA
Rated frequency 50Hz or 60Hz
Rated secondary current 5A or 1A
Rated short-time thermal current 80kA, 1S
Rated dynamic current 160kA
Rated insulation level 40.5/95/200KV
Using type Indoor
Application Measurement and Protection
Insulation class E
FS ≤10
Mechanical parameters
Material Epoxy resin
Weight (kg) 80
Operating conditions
Operating temperature -25°C to +55°C
Daily average temp <+40°C
Storage temperature -40°C to +70°C
Altitude <1000 meters
Condition No existence of severely begrimed, erosive and radioactive gas in the air. Permission of long-term operation under rated current.

TECHNICAL DATA

Ratied Primary Current(A) Class Combination Accuracy class and Rated output(VA) Short-time thermal current(kA/S) Rated dynamic current(kA)
0.2(S) 0.5S 10P10
20 0.2(S)/0.5(S)
0.2(S)/5P20
0.5(S)/5P10
0.2(S)/0.5(S)/10P
15 15 25 1.3 3.25
30 2 5
40 3 7.5
50 4.5 11.5
75 6 15
100 9 22.5
150 12 30
200 18 45
300 24 60
400 36 90
500 40 100
600-800 50 120
1000-1200 63 130
1500-2000 80 160