>Product>Electrical Test Equipment>Power & Energy Reference Standard>1000v & 500a Range Dc Reference Energy Meter
The model GF111D high precision DC reference energy meter are used in electric power, metrology, military industry, manufacturing and scientific research institutes and other DC measurement fields or laboratories. Characteristic features of the GF111D are its wide measuring range, high accuracy and high tolerance to unwanted external influences. Its voltage range from 0 to 1200V, current range from 0 to 600A, DC reference standard of accuracy 0.02% or 0.01%. The 111D DC reference standard offers high functionality combined with an excellent menu guided operation via built-in keyboards and colored 8 inch color touch LCD-display. It can automatically test DC energy meter error, energy accumulation , error of time of day.
■ 0-600A/0-1200V;
■ 8 inch TFT touch screen;
■ Accuracy 0.02% or 0.01%;
■ Using 24bit A/D sampling technology;
■ Recorder 10000 sets energy meter data;
■ Electrical isolation between U and I channels;
■ Programmable multi-plan for testing DC meter;
■ ISO17025 electrical metrology laboratory standard;
■ User friendly menu guided operation;
■ As high precision DC reference standard;
■ DC electric energy accumulation function;
■ Easy verification and analysis of DC meter;
■ Testing all kinds of DC ammeter, DC voltmeter;
■ Statistical U & I of maximum and minimum values;
■ Automatic operation without need of an external PC;
■ Testing all kinds of DC energy meter, DC power meter;
Electrical parameters | |
---|---|
Accuracy | 0.05%, 0.02%, 0.01% |
Power Supply | One Phase AC 180-265V, frequency 50/60Hz. |
Power consumption | 20VA |
DC Voltage Measurement | |
Range | 10mV, 100mV, 1V, 10V, 30V, 100V, 300V, 1000V (max 1200V) |
Accuracy | ±(0.012%RD+0.008%RG) |
DC Current Measurement | |
Range | 0.7mA, 3.5mA, 14mA, 35mA, 140mA, 700mA, 1A, 2A, 5A, 10A, 20A, 50A, 100A, 500A (max 600A) |
Accuracy | ±(0.012%RD+0.008%RG) |
DC Power Measurement | |
power accuracy | ±0.02%, 0.01% |
DC Power Energy Measurement Error | |
power energy | ±0.02%, 0.01% |
Power Pulse Output | |
Power Pulse Output | 20KHz |
Power Pulse Input | |
Energy pulse input | 20KHz |
Function | |
LCD Display | 8 inch 800x600 touch TFT |
Energy accumulation | Yes |
Self-calibration | Yes |
Data storage | Yes |
PC software | Optional |
Communication port | USB, RS232, 10/100M LAN |
Standard | |
Standard | IEC 62053-21,22, 23; IEC 60736; ANSI C12.20-2002; JJG-842-2017; JJG596-2012; JJG 1085-2013; JJF 68-2019; DL/T 1478-2015; DL/T 448-2016; GB/T 33708-2017 |
Safety | |
Isolation protection | IEC 61010-1:2001 |
Measurement Category | 300 V CAT III, 600 V CAT II |
Degree of protection | IP40 |
Declaration of conformity | CE & CNAS certified |
Mechanical parameters | |
Dimensions (W×H×D) (mm) | 400x440x290 |
Weight (kg) | 12 |
Environmental conditions | |
Ambient temperature | -10°C to +40°C |
Storage temperature | -20°C to +65°C |
Relative humidity | 10%-85% |
Temperature coefficient | ≤0.0005% /℃ |
Influence of external fields | ≤0.05 %/mT |
(1) RG means range, the same as below; (2) RD means the setted harmonic content, harmonic can be a single output, also multiple output. |