>Product>Power Meter>Power Transducer>4-20ma 3p3w Active And Reactive Power Transducer
GFUVE FUD-P3/Q3 three phase active power & reactive power transducers measure power in 3 Phase 3 Wire in balanced or unbalanced electrical systems and converts it to an industry standard output signal which is directly proportional to the measured input. It support RS485 port. It adopted SCM technique; excellent stability. Delivering the direction of measured power accurately, applicable for active/reactive power measurement in 3P3W. These Transducers provide an output which is load independent and isolated from the input. These Transducers can measure both Import and Export of Power. The output can be connected to Controllers, Data-Loggers, PLC's Analog/Digital Indicators, Recorders for display, analysis or control. They are ideal for SCADA, Energy Management, Telemetering for Remote, Local as well as Central Monitoring System.
■ Oil system;
■ Power plant;
■ Industrial filed;
■ Coal auto system;
■ Rail electrical system;
■ Electricity power company;
■ Metallurgy electrical system;
■ Excellent linear transducer;
■ Standard DIN install 35mm;
■ 3P3W active power transducer;
■ 3P3W reactive power transducer;
■ Adopted SCM technique; excellent stability;
■ Accuracy class can be reach 0.2% or 0.5%;
■ 220V/5A, 100V/5A, 57.7V/5A, 380V/5A optional;
■ 4-20mA or 4-12-20mA DC signal output optional;
■ 5000 Volts Industry Best Surge Withstand Capability;
■ Applicable for 3P3W active/reactive power measurement;
■ Provides real-time analog signals to SCADA and energy management systems;
Technical Index | |
---|---|
Standard | GB/T 13850-1998, IEC688:1992 |
Accuracy | 0.2%, 0.5% |
Consumption | ≤5VA |
Accuracy drift | Annual variation <0.2% |
Insulation voltage | AC 2kV/min.1mA (Between input-output/power) |
Insulation resistance | ≥20MΩ (DC500V) |
Surge voltage | 5KV (Peak value), 1.2/50μs |
Response time | ≤350ms |
Input range | AC 0-5A ,AC 0-500V(Option), 50/60Hz |
Absorbed power | Per phase voltage: ≤0.5VA/100V Per phase current: <0.1VA/5A |
Overload | Current: 2 times continuous, 30 times/1s; |
Load resistance | Current output: RL ≤650Ω |
Voltage output: RL ≥2kΩ | |
Working environment | Temperature: -10 to +50°C |
RH: 20-90%, without condensation | |
Storage conditions | Temperature: -40 to +70°C |
RH: 20-95%, without condensation | |
Installation | 35mm DIN sliding-way or M4 screws |
Dimension | 110mm x 75mm x 66.9mm |
FUD-Type-Input-Power Supply-Output | |
---|---|
Type | P3: 3P3W active power transducer Q3: 3P3W reactive power transducer PQ3: 3P3W active and reactive power transducer |
AC input | V1: 100V, V2: 0-220V, V3: 270V, V4: 400V A1: 0-1A, A2: 0-5A. |
Power supply | P1: AC 85-265V or DC 100-330V, P2: DC 20-60V. |
DC output | O1: 0-20mA, O2: 0-±20mA, O3: 4-20mA, O4: 4-12-20mA, O5: 0-1V, O6: 0-±1V, O7: 0-5V, O8: 0-±5V, O9: RS485. |
Example 1: FUD-P3-V1-A2-P2-O4 | |
FUD series 3P3W active power transducer | Input: AC100V, ±5A , ±866W Power supply: DC 20-60V Output: 4-12-20mA DC |
Example 2: FUD-PQ3-V1-A2-P2-O4 | |
FUD series 3P3W active and reactive power transducer | Input: AC100V, ±5A , ±866W(var) Power supply: DC 20-60V Output: 4-12-20mA DC |
*Please check the type, input range, output range and power supply when your order the product. |