>Product>Electrical Test Equipment>Primary Injection Test Equipment>2000a Primary Current Injection Tester For Protection Relay

primary injection tester
primary injection tester
primary injection tester
primary injection tester
primary injection tester
primary injection tester
primary injection tester
primary injection tester

TEST-9022000A PRIMARY CURRENT INJECTION TESTER FOR PROTECTION RELAY

TEST-902 2000A primary current injection tester adopts ARM chip to control the output process and large capacity of toroidal transformer. It is equipped with LCD screen display current meter, also showed primary current value, secondary current value, turn ratio and the action time. Aluminum alloy body with PC panel component the shell. TEST-902 primary current injection tester is mainly applied to test CT turn ratio and polarity in the power system, the contact resistance, protection relay, low voltage & high voltage circuit breaker protection test and high voltage generator test etc, which need large current on-site or in the lab.

FEATURES

■ Portable designed

■ Quick and easy to use

■ With CT ratio test function

■ With 6m large current cable

■ Max current output up to 2200A

■ Built-in digital timer resolution 1 ms

■ Built-in digital ammeter 0.5% accuracy

■ Permanent current up to 2000 A, 12KVA

■ Made up of two units, control and power unit

■ Thermal, short-circuit and overload protection

APPLICATION

■ Switchgear Testing

■ Ground Grid Testing

■ Circuit Breaker Testing

■ Protective Relay Testing

■ Current Transformer Testing

■ Recloser and Sectionalizers

■ 2000A Primary injection tests

PARAMETERS

Electrical parameters
Accuracy ±0.5%
Power Supply (AC) 220V±10%·50A, 50Hz/60Hz or 110V±10%·100A, 50Hz/60Hz
Current Output (AC) 2000A·6V or 1000A·12V
Capacity 12KVA
The current output waveform distortion ≤5%
Primary current
Range 0-2200A
Resolution 0.1A
Accuracy <0.5%
Secondary measurement
Range 0-6A
Resolution 0.001A
Accuracy <0.5%
Current duration
2000A range 2000A   2-3minutes
1000A   3-6minutes
1000A range 1000A   2-3minutes
Continuous output 800A
With timer
Range 0.0001~999.999S
Resolution 0.001S
Accuracy <0.2% ±5 words
Standard
Standard IEC61010-1;IEC 61326-1
Communication port RS232
Cable length 4x6m, 95mm²
Mechanical parameters
Dimensions (W×D×H) (mm) 360×300×295 and 320×300×300
Weight(kg) Control Host 35kg, External voltage regulator weight 15kg
Structure Integrated or split optional
Environmental conditions
Operating Temperature -10°C to 50°C
Storage Temperature -40°C to 70°C
Relative humidity ≤95%,on-condensing

SELECTION GUIDE

Model Accuracy Primary Current Ammeter(0-6A) Timer Power Injection Current time Dimension(W×D×H) (mm) Weight Remark
TEST-901 0.5% 0-1100A YES YES 5KVA 1000A: 2-3min;
500A:3-6min
430×260×260 25KG Integrated structure
TEST-902 0.5% 0-2200A YES YES 12KVA 2000A:2-3min;
1000A:3-6min
360×300×295 and 320×300×300 35KG+15KG Fission structure
TEST-903 0.5% 0-3300A YES YES 15KVA 3000A: 2-3min;
1500A:3-6min
380×350×360 and 340×290×420 48KG+42KG Fission structure
TEST-905 0.5% 0-5500A YES YES 30KVA 5000A:2-3min;
2500A:3-6min
430×430×445 and 550×450×600 68KG+55KG Fission structure