EV charging pile calibrator
EV charging pile calibrator
EV charging pile calibrator
EV charging pile calibrator

GF1119EV & CHARGING PILE DC TEST SET

GF1119 EV & Charging pile DC on-site comprehensive test set for off-board charger integrates some functions such as on-site calibrator, power analyzer, oscillographic recorder, BMS simulator software, vehicle DC interface circuit simulation box, insulation resistance tester and so on. It cooperates with the load to meet the test requirements of metrological verification, interoperability test and protocol consistency test, and meet the requirements of test items in the acceptance stage and operation stage of State Grid No. 45 document. Interoperability detection process, real-time graphical display of waveform and message, and clear working status at a glance. The device has built-in WiFi module, data can be transmitted wirelessly, and remote control can be realized through wireless devices such as tablet computers. Technically, GF1119 uses various cutting-edge technologies to make the equipment high-performance, such as 24bit sigma delta ad, imported high stability zero flux transformer and dual core DSP with main frequency of 500M.

APPLICATION

■ Electrical laboratory; ■ EV & Charging pile factory; ■ Metrological service center; ■ Laboratories of power utilities; ■ Third party testing organization; ■ Electricity power bureau & power company; ■ National Metrology and testing department; ■ Charging pile operation and maintenance organization;

TEST ITEM

■ CP interrupt test;

■ CC interrupt test;

■ CP grounding test;

■ Output overcurrent test;

■ Charging readiness test;

■ Testing of working error;

■ Display error verification;

■ CP loop voltage limit test;

■ JJG 1148-2018 Standard;

■ Normal charging end test;

■ Insulation resistance test;

■ Disconnect switch S2 test;

■ Connection confirmation test;

■ GB/T 34657.1-2017 Standard;

■ Testing of clock indication error;

■ Testing of payment amount error;

■ Start up and charging phase test;

■ Temperature and humidity detection;

■ Charging connection control sequence test;

■ Continuity loss test of protective grounding conductor;

FEATURES & FUNCTIONS

■ High accuracy 0.05%;

■ simulator, power analyzer etc;

■ Automatic and manual test optional;

■ Using 24bit A/D sampling technology;

■ Recorder 10000 sets energy meter data;

■ Wide range design from 0-300A/0-1200V DC;

■ With Li-battery, working more than 8 hours;

■ ISO17025 electrical metrology laboratory standard;

■ Portable, small size, drag bar box structure design;

■ Built in WIFI, it can be controlled by PDA, PC computer;

■ Programmable multi-plan for testing EV & DC Charging pile;

■ Commissioning experience of 100 models EV & DC charging pile;

■ Using multi closed loop zero flux sensor and PGA Technology;

■ Safety test, performance test, Compatibility test, Metrological test;

■ According to JJG 1149-2018, GB/T 34657.1-2017 & GB/T34658-2017 Standard;

■ Internal high-voltage and low-voltage isolation to protect the safety of operators;

■ Integrated design concept, built-in reference meter, insulation resistance tester, oscilloscope, interface;

PARAMETERS

Electrical parameters
Accuracy class 0.05%
Power supply One Phase AC 100-265V, frequency 50/60Hz; Li-battery
Power consumption <100VA
DC Voltage Measurement
Range 0-1000V (max 1200V)
Accuracy ±0.02%
DC Current Measurement
Range 0-300A
Accuracy ±0.02%
DC Power Measurement
Accuracy ±0.05%(1V-1000V, 5A-300A)
DC Power Energy Measurement Error
Power energy ±0.05%(1V-1000V, 5A-300A)
Power Pulse Output
Power Pulse Output 0 - 100KHz , >20mA, one channel, level 5V
Energy Pulse Input
Energy pulse input 0 - 100KHz, one channel, level 3-12V
Ripple Measurement
Range 1Hz-6KHz
Accuracy ±0.5%
Insulation Resistance Measurement
Voltage Range 0-1000V
Resistance range 0-50MΩ
Accuracy ±5% (1~50MΩ)
Power Analyzer(AC)
AC voltage input(L1\L2\L3\N) 220V±20% (±0.05%RD)
AC current input(IL1\IL2\IL3) 0.1-500A(±0.5%RG) (current sensor optional)
Accuracy ±0.5%
Voltage harmonic times 2-127 times
Current harmonic times 2-127 times
Wave Recorder Measurement
Voltage input Range 0-±1000V
Accuracy ±1%RG
Waveform Capture Resolution 10us
CAN Baud Rate 250kbit/s
Temperature Measurement
Range -40°C to +80°
Accuracy ±0.2°C
Resolution 0.1°C
Humidity Measurement
Range 0%RH-99.99%RH
Accuracy ±5%RH
Resolution 0.1%RH
Function
LCD Display 10 inch 800x600 touch TFT
Energy accumulation Yes
Self-calibration Yes
Data storage Yes
Auto test Yes
GPS Yes
Test Report (word file) download Yes
PC software Optional
Communication port USB, RS232, WIFI, 10/100M LAN
Standard
Standard IEC 62053-21,22, 23; IEC 60736; ANSI C12.20-2002;
JJG-842-2017; JJG596-2012; JJG 1085-2013; JJG 1049-2018;
JJF 68-2019; DL/T 1478-2015; DL/T 448-2016; GB/T 33708-2017; JJG 1148-2018; GB/T 34657.1-2017
Safety
Isolation protection IEC 61010-1:2001
Measurement Category 300 V CAT III, 600 V CAT II
Degree of protection IP65
Declaration of conformity CE & CNAS certified
Mechanical parameters
Dimensions (W×D×H) (mm) 570x418x285
Weight (kg) 20
Environmental conditions
Ambient temperature -20°C to +50°C
Storage temperature -30°C to +65°C
Relative humidity 10%-85%
Temperature coefficient ≤0.005% /℃
Influence of external fields ≤0.05 %/mT