GF1115 EV & charging pile AC on-site comprehensive test set integrates some functions such as on-site calibrator, oscillograph recorder, vehicle AC interface circuit simulation box, insulation resistance tester and leakage state simulator. It cooperates with the load, meets the test requirements of metrological verification and interoperability test, and fully meets the requirements of test items inspected in the acceptance stage and operation stage of State Grid. Interoperability detection process, real-time graphical display of waveform, and clear working state at a glance. The device has built-in WiFi module, and the data can be transmitted wirelessly through the tablet. And other wireless devices to achieve remote control. Technically, GF1115 uses various cutting-edge technologies to achieve high performance, such as 24bit high-speed and high-precision synchronous sampling AD and 500m dual core DSP CPU.
■ Electrical laboratory; ■ EV & Charging pile factory; ■ Metrological service center; ■ Laboratories of power utilities; ■ Third party testing organization; ■ Electricity power bureau & power company; ■ National Metrology and testing department; ■ Charging pile operation and maintenance organization;
■ As a waveform recorder;
■ Wide range 0-480V/0-80A;
■ With PC software optional;
■ Waveform display function;
■ High stability, high reliability;
■ simulator, power analyzer etc;
■ Energy accumulating function;
■ High accuracy class up to 0.05%;
■ Measuring 2nd~127nd harmonics;
■ Automatic generation of test report;
■ Metal structure, strong and reliable;
■ Automatic and manual test optional;
■ Using 24bit AD sampling technology;
■ With Li-battery, working more than 8 hours;
■ Portable, small size, drag bar box structure design;
■ Suit for testing EV & Charging AC pile error on site;
■ Built in WIFI, it can be controlled by PDA, PC computer;
■ According to JJG 1149-2018 & GB/T 34657.1-2017 Standard;
■ Safety test, performance test, Compatibility test, Metrological test;
■ Integrated design concept, built-in reference meter, insulation resistance tester, oscilloscope, interface;
■ CP interrupt test;
■ CP grounding test;
■ CC interrupt test;
■ Testing of working error;
■ Output overcurrent test;
■ Charging readiness test;
■ Display error verification;
■ Insulation resistance test;
■ CP loop voltage limit test;
■ JJG 1148-2018 Standard;
■ Normal charging end test;
■ Disconnect switch S2 test;
■ Connection confirmation test;
■ GB/T 34657.1-2017 Standard;
■ Testing of clock indication error;
■ Testing of payment amount error;
■ Start up and charging phase test;
■ Temperature and humidity detection;
■ Charging connection control sequence test;
■ Continuity loss test of protective grounding conductor;
Electrical parameters | |
---|---|
Accuracy class | 0.05% |
Power supply | One Phase AC 100-265V, frequency 50/60Hz; Li-battery |
Power consumption | <100VA |
Voltage measurement | |
Range | 380V (0-480.000V) |
Error | ±0.02% (30V-480V) |
Harmonic | 2nd-127th |
Current measurement | |
Range | 63A (0-80.000A) |
Error | ±0.02% (1A-80A) |
Harmonic | 2nd-127th |
Power measurement error | |
Active power | ±0.05% (1A-80A,30-480V) |
Energy measurement error | |
Active energy | ±0.05% (50%-120%Un)/(1%-110%In) |
Phase angle | |
Range | 0°-360.000° |
Resolution | 0.01° |
Error | ±0.02° |
Power factor | |
Range | -1.00000-0-1.00000 |
Resolution | 0.00005 |
Error | 0.00001 |
Frequency | |
Range | 45.0000-65.0000Hz |
Resolution | 0.001 |
Error | ±0.005 |
Pulse output | |
Output channel | 1 |
Energy constant | 1-9999999 |
Pulse ratio | 1:1 |
Output level | 5V |
Output rated frequency | 0-100KHz |
Pulse input | |
Input channel | 1 |
Input level | 3-12V |
Input frequency | 0-100KHz |
Insulation Resistance Measurement | |
Voltage Range | 0-1000V |
Resistance range | 0-50MΩ |
Accuracy | ±5% (1~50MΩ) |
Power Analyzer(AC) | |
AC voltage input(L1\L2\L3\N) | 220V±20% (±0.05%RD) |
AC current input(IL1\IL2\IL3) | 0.1-500A(±0.5%RG) (current sensor optional) |
Accuracy | ±0.5% |
Voltage harmonic times | 2-127 times |
Current harmonic times | 2-127 times |
Wave Recorder Measurement | |
Voltage input Range | 0-±1000V |
Accuracy | ±1%RG |
Waveform Capture Resolution | 10us |
CAN Baud Rate | 250kbit/s |
Temperature Measurement | |
Range | -40°C to +80°C |
Accuracy | ±0.2°C |
Resolution | 0.1°C |
Humidity Measurement | |
Range | 0%RH-99.99%RH |
Accuracy | ±5%RH |
Resolution | 0.1%RH |
Function | |
LCD Display | 10 inch 800x600 touch TFT |
Energy accumulation | Yes |
Self-calibration | Yes |
Data storage | Yes |
Auto test | Yes |
GPS | Yes |
Test Report (word file) download | Yes |
PC software | Optional |
Communication port | RS232, USB, WIFI, 10/100M LAN |
Standard | |
Standard | IEC 62053-21,22, 23; IEC 60736; ANSI C12.20-2002; JJG 597-2005; JJG596-2012; JJG 1085-2013; JJG 1148-2018; GB/T 34657.1-2017; JJF 68-2019; DL/T 826-2002; DL/T 1478-2015; DL/T 448-2016; |
Safety | |
Isolation protection | IEC 61010-1:2001 |
Measurement Category | 300 V CAT III, 600 V CAT II |
Degree of protection | IP65 |
Declaration of conformity | CE & CNAS certified |
Mechanical parameters | |
Dimensions (W×D×H) (mm) | 570×418×285 |
Weight (kg) | 19 |
Environmental conditions | |
Ambient temperature | -20°C to +50°C |
Storage temperature | -30°C to +65°C |
Relative humidity | 10%-85% |
Temperature coefficient | ≤0.005% /℃ |
Influence of external fields | ≤0.05 %/mT |