>Product>Electrical Test Equipment>EV & Recharging Testing>Portable Ev & Charging Pile Ac Test Set

EV charging pile ac test set
EV charging pile ac test set
EV charging pile ac test set
EV charging pile ac test set

GF1115PORTABLE EV & CHARGING PILE AC TEST SET

GF1115 EV & charging pile AC on-site comprehensive test set integrates some functions such as on-site calibrator, oscillograph recorder, vehicle AC interface circuit simulation box, insulation resistance tester and leakage state simulator. It cooperates with the load, meets the test requirements of metrological verification and interoperability test, and fully meets the requirements of test items inspected in the acceptance stage and operation stage of State Grid. Interoperability detection process, real-time graphical display of waveform, and clear working state at a glance. The device has built-in WiFi module, and the data can be transmitted wirelessly through the tablet. And other wireless devices to achieve remote control. Technically, GF1115 uses various cutting-edge technologies to achieve high performance, such as 24bit high-speed and high-precision synchronous sampling AD and 500m dual core DSP CPU.

APPLICATION

■ Electrical laboratory; ■ EV & Charging pile factory; ■ Metrological service center; ■ Laboratories of power utilities; ■ Third party testing organization; ■ Electricity power bureau & power company; ■ National Metrology and testing department; ■ Charging pile operation and maintenance organization;

FEATURES

■ As a waveform recorder;

■ Wide range 0-480V/0-80A;

■ With PC software optional;

■ Waveform display function;

■ High stability, high reliability;

■ simulator, power analyzer etc;

■ Energy accumulating function;

■ High accuracy class up to 0.05%;

■ Measuring 2nd~127nd harmonics;

■ Automatic generation of test report;

■ Metal structure, strong and reliable;

■ Automatic and manual test optional;

■ Using 24bit AD sampling technology;

■ With Li-battery, working more than 8 hours;

■ Portable, small size, drag bar box structure design;

■ Suit for testing EV & Charging AC pile error on site;

■ Built in WIFI, it can be controlled by PDA, PC computer;

■ According to JJG 1149-2018 & GB/T 34657.1-2017 Standard;

■ Safety test, performance test, Compatibility test, Metrological test;

■ Integrated design concept, built-in reference meter, insulation resistance tester, oscilloscope, interface;

TEST ITEM

■ CP interrupt test;

■ CP grounding test;

■ CC interrupt test;

■ Testing of working error;

■ Output overcurrent test;

■ Charging readiness test;

■ Display error verification;

■ Insulation resistance test;

■ CP loop voltage limit test;

■ JJG 1148-2018 Standard;

■ Normal charging end test;

■ Disconnect switch S2 test;

■ Connection confirmation test;

■ GB/T 34657.1-2017 Standard;

■ Testing of clock indication error;

■ Testing of payment amount error;

■ Start up and charging phase test;

■ Temperature and humidity detection;

■ Charging connection control sequence test;

■ Continuity loss test of protective grounding conductor;

PARAMETERS

Electrical parameters
Accuracy class 0.05%
Power supply One Phase AC 100-265V, frequency 50/60Hz; Li-battery
Power consumption <100VA
Voltage measurement
Range 380V (0-480.000V)
Error ±0.02% (30V-480V)
Harmonic 2nd-127th
Current measurement
Range 63A (0-80.000A)
Error ±0.02% (1A-80A)
Harmonic 2nd-127th
Power measurement error
Active power ±0.05% (1A-80A,30-480V)
Energy measurement error
Active energy ±0.05% (50%-120%Un)/(1%-110%In)
Phase angle
Range 0°-360.000°
Resolution 0.01°
Error ±0.02°
Power factor
Range -1.00000-0-1.00000
Resolution 0.00005
Error 0.00001
Frequency
Range 45.0000-65.0000Hz
Resolution 0.001
Error ±0.005
Pulse output
Output channel 1
Energy constant 1-9999999
Pulse ratio 1:1
Output level 5V
Output rated frequency 0-100KHz
Pulse input
Input channel 1
Input level 3-12V
Input frequency 0-100KHz
Insulation Resistance Measurement
Voltage Range 0-1000V
Resistance range 0-50MΩ
Accuracy ±5% (1~50MΩ)
Power Analyzer(AC)
AC voltage input(L1\L2\L3\N) 220V±20% (±0.05%RD)
AC current input(IL1\IL2\IL3) 0.1-500A(±0.5%RG) (current sensor optional)
Accuracy ±0.5%
Voltage harmonic times 2-127 times
Current harmonic times 2-127 times
Wave Recorder Measurement
Voltage input Range 0-±1000V
Accuracy ±1%RG
Waveform Capture Resolution 10us
CAN Baud Rate 250kbit/s
Temperature Measurement
Range -40°C to +80°C
Accuracy ±0.2°C
Resolution 0.1°C
Humidity Measurement
Range 0%RH-99.99%RH
Accuracy ±5%RH
Resolution 0.1%RH
Function
LCD Display 10 inch 800x600 touch TFT
Energy accumulation Yes
Self-calibration Yes
Data storage Yes
Auto test Yes
GPS Yes
Test Report (word file) download Yes
PC software Optional
Communication port RS232, USB, WIFI, 10/100M LAN
Standard
Standard IEC 62053-21,22, 23; IEC 60736; ANSI C12.20-2002;
JJG 597-2005; JJG596-2012; JJG 1085-2013; JJG 1148-2018;
GB/T 34657.1-2017; JJF 68-2019; DL/T 826-2002; DL/T 1478-2015; DL/T 448-2016;
Safety
Isolation protection IEC 61010-1:2001
Measurement Category 300 V CAT III, 600 V CAT II
Degree of protection IP65
Declaration of conformity CE & CNAS certified
Mechanical parameters
Dimensions (W×D×H) (mm) 570×418×285
Weight (kg) 19
Environmental conditions
Ambient temperature -20°C to +50°C
Storage temperature -30°C to +65°C
Relative humidity 10%-85%
Temperature coefficient ≤0.005% /℃
Influence of external fields ≤0.05 %/mT