>Product>Power Meter>Power Transducer>Three Phase Ac Current Voltage Transducer With 4-20ma Output
FUD-3I/3U 3 phase AC voltage transducer or three phase AC current transducer is a special voltage sensor or current sensor for three-phase AC voltage measurement or current measurement. Voltage transducer has a measuring range from AC 0V to 500V, current transducer has a measuring range 1A/5A, supply voltage supply AC/DC 85V-300V, output signal DC 0-5V/0-20mA/4-20mA. 3 phase voltage transducer is mainly used for power monitoring, power control and dispatching systems in petroleum, coal, metallurgy, railway, power plant and other industries. Change the measured AC current/voltage to the DC current/voltage output according to the linear scale,Excellent temperature characteristic and good working stability, Configuration compactness and briefness.
■ Oil system;
■ Power plant;
■ Coal auto system;
■ Industrial filed;
■ Rail electrical system;
■ Electricity power company;
■ Metallurgy electrical system;
■ Standard DIN install;
■ Excellent linear transducer;
■ AC current / voltage transducer;
■ AC input range can be customized;
■ AC input range can be customized;
■ DC output range can be customized;
■ DC output range can be customized;
■ Accuracy class can reach 0.2% or 0.5%;
■ Three phase current / voltage transducer;
■ Working at wide temperature characteristics;
■ 85-265V AC/DC and 20-60V DC power supply optional;
Technical Index | |
---|---|
Standard | GB/T 13850-1998, IEC688:1992 |
Accuracy | 0.2%, 0.5% |
Consumption | ≤3VA |
Accuracy drift | Annual variation < 0.2% |
Insulation voltage | AC 2kV/min.1mA (Between input- output / power) |
Insulation resistance | ≥20MΩ (DC500V) |
Surge voltage | 5KV (Peak value), 1.2/50μs |
Response time | ≤350ms |
Input range | AC 0-10A ,AC 0-500V(Option), 50/60Hz |
Absorbed power | <0.5VA/450V, <0.2VA/100V, <0.1VA/5A |
Overload | Current: 2 times continuous, 30 times /1s; | Voltage: 2 times continuous |
Load resistance | Current output: RL ≤550Ω |
Voltage output: RL ≥2kΩ | |
Working environment | Temperature: -10 to +50°C |
RH: 20-90%, without condensation | |
Storage conditions | Temperature: -40 to +70°C |
RH: 20-95%, without condensation | |
Installation | 35mm DIN sliding-way or M4 screws |
Dimension | 110mm x 75mm x 120mm |
FUD-Type-Input-Power Supply-Output | |
---|---|
Type | 3I: Three phase AC current transducer |
3U: Three phase AC voltage transducer | |
AC input | A1: 0-1A, A2: 0-5A, A3: 0-10A. |
V0: 0-70V, V1: 0-120V, V2: 0-250V. | |
V3: 0-300V, V4: 0-450V, V5: 0-500V. | |
Power supply | P1: AC 85-265V or DC 100-330V, P2: DC 20-60V. |
DC output | O1: 0-5V, O2: 1-5V, O3: 0-20mA, O4: 4-20mA, O5: RS485. |
Example 1: FUD-3I-A2-P1-O4 | |
FUD series three phase AC current transducer | Input: AC 0-5A |
Power supply: AC220V±15% | |
Output: DC4-20mA | |
Example 2: FUD-3U-V2-P1-O4 | |
FUD series three phase AC voltage transducer | Input: AC 0-250V |
Power supply: AC220V±15% | |
Output: DC4-20mA | |
*Please check the type, input range, output range and power supply when your order the product. |