>Product>Power Meter>Power Transducer>Three Phase Ac Current Voltage Transducer With 4-20ma Output

voltage current transducer
voltage current transducer

FUD-3I/3U THREE PHASE AC CURRENT VOLTAGE TRANSDUCER WITH 4-20MA OUTPUT

FUD-3I/3U 3 phase AC voltage transducer or three phase AC current transducer is a special voltage sensor or current sensor for three-phase AC voltage measurement or current measurement. Voltage transducer has a measuring range from AC 0V to 500V, current transducer has a measuring range 1A/5A, supply voltage supply AC/DC 85V-300V, output signal DC 0-5V/0-20mA/4-20mA. 3 phase voltage transducer is mainly used for power monitoring, power control and dispatching systems in petroleum, coal, metallurgy, railway, power plant and other industries. Change the measured AC current/voltage to the DC current/voltage output according to the linear scale,Excellent temperature characteristic and good working stability, Configuration compactness and briefness.

APPLICATION

■ Oil system;

■ Power plant;

■ Coal auto system;

■ Industrial filed;

■ Rail electrical system;

■ Electricity power company;

■ Metallurgy electrical system;

FEATURES

■ Standard DIN install;

■ Excellent linear transducer;

■ AC current / voltage transducer;

■ AC input range can be customized;

■ AC input range can be customized;

■ DC output range can be customized;

■ DC output range can be customized;

■ Accuracy class can reach 0.2% or 0.5%;

■ Three phase current / voltage transducer;

■ Working at wide temperature characteristics;

■ 85-265V AC/DC and 20-60V DC power supply optional;

Technical Index

Technical Index
Standard GB/T 13850-1998, IEC688:1992
Accuracy 0.2%, 0.5%
Consumption ≤3VA
Accuracy drift Annual variation < 0.2%
Insulation voltage AC 2kV/min.1mA (Between input- output / power)
Insulation resistance ≥20MΩ (DC500V)
Surge voltage 5KV (Peak value), 1.2/50μs
Response time ≤350ms
Input range AC 0-10A ,AC 0-500V(Option), 50/60Hz
Absorbed power <0.5VA/450V, <0.2VA/100V, <0.1VA/5A
Overload Current: 2 times continuous, 30 times /1s;
Voltage: 2 times continuous
Load resistance Current output: RL ≤550Ω
Voltage output: RL ≥2kΩ
Working environment Temperature: -10 to +50°C
RH: 20-90%, without condensation
Storage conditions Temperature: -40 to +70°C
RH: 20-95%, without condensation
Installation 35mm DIN sliding-way or M4 screws
Dimension 110mm x 75mm x 120mm

Model Description

FUD-Type-Input-Power Supply-Output
Type 3I: Three phase AC current transducer
3U: Three phase AC voltage transducer
AC input A1: 0-1A, A2: 0-5A, A3: 0-10A.
V0: 0-70V, V1: 0-120V, V2: 0-250V.
V3: 0-300V, V4: 0-450V, V5: 0-500V.
Power supply P1: AC 85-265V or DC 100-330V, P2: DC 20-60V.
DC output O1: 0-5V, O2: 1-5V, O3: 0-20mA, O4: 4-20mA, O5: RS485.
Example 1: FUD-3I-A2-P1-O4
FUD series three phase AC current transducer Input: AC 0-5A
Power supply: AC220V±15%
Output: DC4-20mA
Example 2: FUD-3U-V2-P1-O4
FUD series three phase AC voltage transducer Input: AC 0-250V
Power supply: AC220V±15%
Output: DC4-20mA
*Please check the type, input range, output range and power supply when your order the product.