>Product>Current Probe>AC Current Clamp>1000a Cable Fault Analysis Clamp Current Transformer
The P110 clamp current transformer is a high performance AC Clamp current probe with excellent transformation and low phase shift. The high quality magnetic permalloy core and uniform windings provide for accurate measurements up to 1000AAC/250AAC/600AAC. The "ring type" jaw permits good magnetic conduction and cable positionings. Provide excellent RMS capabilities and reliable signal reproduction.
DESCRIPTIONIt is well suited for power quality applications where high accuracy and low phase shift along with wide frequency from 10Hz to 2MHz are important. Measurement range is 1mA to 1200A.
The P110 current transformer clamp is a general purpose 1000A AC current probe designed for use with DMMs, cable fault analysis and loggers instruments that have a current input. It has a 1000:1 ratio and output of 1mA per amp or 1mV per amp measured in the jaw. The P110 clamp ct has an integral 2.5m or 5m lead terminated. The rounded jaw design on this probe makes it well-suited for cable fault analysis applications where high accuracy and low phase shift and wide frequency.
■ Waveform analysis;
■ Cable Fault Analysis;
■ Power load monitoring;
■ Leakage current meter;
■ Earth resistance meter;
■ Large industrial loads;
■ Energy meter calibrator;
■ Power and harmonic meters;
■ Power quality analyzer(PQA);
■ Measuring around cable bundles;
■ Ergonomic design;
■ UL, CE CNAS mark;
■ Frequency 10-2MHz;
■ 1mA/A or 1mV/A signal output;
■ Holding wire diameter: φ110mm;
■ Transformation ratio: 1000:1, 1000:5;
■ Conforms to EN 61010, 600V CAT III;
■ Low phase shift for power measurement;
■ Measurement range of 1mA to 1200A AC;
■ High content nickel metal permalloy core;
■ Improved ergonomic design & easy operation;
■ Designed for DMMs, recorders, loggers, power and harmonic meters, oscilloscopes;
Electrical parameters | |
---|---|
Ratio | 1000: 1 or 2000:1 (customized) |
Accuracy class | 0.1%, 0.2%, 0.5%, 1% |
Primary current | 0 - 1000A AC |
Secondary voltage | 0-10V AC (customized) |
Secondary current | 0-1A AC or 0 - 5A AC (customized) |
Max. Cont. Input current | 1200A |
Over voltage category | CAT III 600V |
Output signal (AC current) | 250mA, 500mA,1A,5A AC at nominal input current |
Output signal (AC voltage) | 1V, 5V, 10V AC at nominal input current |
Frequency range | 10Hz-2MHz |
Dielectric strength | 3KV 50Hz/60Hz at 1 minute |
Temperature range | -40°C to +55°C |
Output | 2.5 meter cable with D01 connector |
Max. voltage not insulated conductors | 720 V |
Standard | EN 61010-1, EN 61010-2-032, EN 61010-2-031 IEC60044-1, & IEC61869-2, 600V CAT III |
Installation | clamp type |
Output mode | lead output(2.5m, 5m or 10m) |
Connector | BNC, 4mm banana, signal cable(2 cores),customized |
Mechanical parameters | |
Dimensions (L x W x H) (mm) | 163 x 310 x 34 |
Weight (g) | 900 |
Holding wire diameter (mm) | φ110 |
Max. jaw opening (mm) | 110 |
Jaw color | Black |
Material | PC+ABS, UL94 V0 |
Model | Rate Current | Max Current | Secondary | Coil Ratio | Burden Resistance | Accuracy |
---|---|---|---|---|---|---|
P110-500 | 500A | 600A | 5A | 100:1 | 2.5VA | 0.5% |
P110-600 | 600A | 720A | 5A | 120:1 | 2.5VA | 0.5% |
P110-800 | 800A | 960A | 5A | 160:1 | 2.5VA | 0.5% |
P110-1000 | 1000A | 1200A | 5A | 200:1 | 2.5VA | 0.5% |
P1101-200 | 200A | 240A | 1A | 200:1 | customized | 0.2% |
P1101-300 | 300A | 360A | 1A | 300:1 | customized | 0.2% |
P1101-400 | 400A | 480A | 1A | 400:1 | customized | 0.2% |
P1101-500 | 500A | 600A | 1A | 500:1 | customized | 0.2% |
P1101-600 | 600A | 720A | 1A | 600:1 | customized | 0.2% |
P1101-800 | 800A | 960A | 1A | 800:1 | customized | 0.2% |
P1101-1000 | 1000A | 1200A | 1A | 1000:1 | customized | 0.1% |
P1102-500 | 500A | 600A | 500mA | 1000:1 | customized | 0.1% |
P1102-600 | 600A | 720A | 500mA | 1200:1 | customized | 0.1% |
P1102-800 | 800A | 960A | 500mA | 1500:1 | customized | 0.1% |
P1102-1000 | 1000A | 1200A | 500mA | 2000:1 | customized | 0.1% |
P1103-800 | 800A | 960A | 400mA | 2000:1 | customized | 0.1% |
P1103-1000 | 1000A | 1200A | 400mA | 2500:1 | customized | 0.1% |
P1104-250 | 250A | 300A | 250mA | 1000:1 | customized | 0.1% |
P1104-500 | 500A | 600A | 250mA | 2000:1 | customized | 0.1% |
P1104-1000 | 1000A | 1200A | 250mA | 4000:1 | customized | 0.1% |
P1105-200 | 200A | 240A | 1V | 1000:1 | customized | 0.1% |
P1105-300 | 300A | 360A | 1V | 1000:1 | customized | 0.1% |
P1105-400 | 400A | 480A | 1V | 1000:1 | customized | 0.1% |
P1105-500 | 500A | 600A | 1V | 1000:1 | customized | 0.1% |
P1105-600 | 600A | 720A | 1V | 1000:1 | customized | 0.1% |
P1105-800 | 800A | 960A | 1V | 1000:1 | customized | 0.1% |
P1105-1000 | 1000A | 1200A | 1V | 1000:1 | customized | 0.1% |
P1106-200 | 200A | 240A | 5V | 1000:1 | customized | 0.1% |
P1106-300 | 300A | 360A | 5V | 1000:1 | customized | 0.1% |
P1106-400 | 400A | 480A | 5V | 1000:1 | customized | 0.1% |
P1106-500 | 500A | 600A | 5V | 1000:1 | customized | 0.1% |
P1106-600 | 600A | 720A | 5V | 1000:1 | customized | 0.1% |
P1106-800 | 800A | 960A | 5V | 1000:1 | customized | 0.1% |
P1106-1000 | 1000A | 1200A | 5V | 1000:1 | customized | 0.1% |
P1108-200 | 200A | 240A | 10V | 1000:1 | customized | 0.1% |
P1108-300 | 300A | 360A | 10V | 1000:1 | customized | 0.1% |
P1108-400 | 400A | 480A | 10V | 1000:1 | customized | 0.1% |
P1108-500 | 500A | 600A | 10V | 1000:1 | customized | 0.1% |
P1108-600 | 600A | 720A | 10V | 1000:1 | customized | 0.1% |
P1108-800 | 800A | 960A | 10V | 1000:1 | customized | 0.1% |
P1108-1000 | 1000A | 1200A | 10V | 1000:1 | customized | 0.1% |